$2,610.00 Original price was: $2,610.00.$2,260.00Current price is: $2,260.00.
The WOODWARD 8237-1246 (ProTech-GII) is a SIL 3-certified configurable overspeed detection system, designed to monitor steam, gas, and hydro turbines, triggering safe shutdown via 2-out-of-3 voted logic upon overspeed/over-acceleration events for critical equipment protection .
| Parameter | Details |
|---|---|
| Model | WOODWARD 8237-1246 (ProTech-GII) |
| Manufacturer | Woodward Inc. |
| Product Type | Configurable Turbine Overspeed Detection & Protection System |
| Core Functions | Overspeed/over-acceleration detection; 2-out-of-3 voted shutdown logic; automatic overspeed test routine; time-stamped alarm/trip logging; Modbus integration |
| Speed Monitoring Range | 0.5 RPM to 32,000 RPM (compatible with turbine speed scales) |
| Input Compatibility | Magnetic speed pickups (MPUs); passive/active speed sensors |
| Output Options | 2 dual redundant trip relays (2-out-of-3 voted); 3 independent non-voted trip relays; 4-20 mA analog speed readout |
| Communication Interface | RS-485; Supported protocol: Modbus RTU |
| Power Supply | 24 V DC (nominal); 18-32 V DC (operating range) |
| Operating Temperature Range | -20°C to +70°C |
| Storage Temperature Range | -40°C to +85°C |
| Relative Humidity | 5% – 95% RH (non-condensing) |
| Protection Rating | IP56 (dust-tight, water-resistant) |
| Dimensions (W × H × D) | 331 mm × 413 mm × 136 mm |
| Weight | 6.8 kg |
| Mounting Type | Panel-mounted |
| Certifications | IEC 61508 SIL 3; API 670; API 612; CE |
| Key Features | Configurable for multiple turbine types; individual module testing via frequency generator; alarm relay integration; rugged industrial enclosure |
| System Compatibility | Steam/gas/hydro turbines; turbine trip valves; magnetic speed sensors; SCADA/HMI via Modbus |
| Applications | Power generation turbines; oil & gas process turbines; marine turbines; industrial rotating machinery safety systems |